Type | Specification |
Trigger modes | Time slices,
Peak (threshold, up- / downslope), Timetable (combination of time intervals and peak) and Manual trigger (supported only with G1323B Control Module) Agilent 1200 Series DAD/MWD detectors (G1315A/B/C, G1365 A/B/C), the Agilent 1200 Series fluorescence detector and the Agilent G1946C/D, G1956A/B LC-MSD are fully supported other detectors can be used but are not supported for fraction collection |
operating modes | Discrete fractions: default mode for all vessels. The flow is diverted to waste, while moving from one vessel position to the next vessel positionContinuous flow: optional, available only when using well plates. It is possible to move from one well plate position to the next one without diverting the flow into the well plate to waste |
Fraction capacities
and trays |
4 x well-plates full tray (MTP)*
(for use with deep well plates, only) 2 × well-plates std. tray (MTP) (for use with deep well plates, only) + 10 × 2 ml vials* (+ 1 half tray) 100 x 2 ml in std. tray (+ 1 half tray)* 3 x 40 x 2 ml in half tray* 3 x 15 x 6 ml in half tray* Full tray with 40 test tubes (30 mm OD, max. height 100 mm, ~45 ml / tube) Full tray with 60 test tubes (25 mm OD, max. height 100 mm, ~25 ml / tube) Full tray with 126 test tubes (16 mm OD, max. height 100 mm, ~12 ml / tube) Full tray with 215 test tubes (12 mm OD, max. height 100 mm, ~7 ml / tube) Installed trays are automatically detected and identified. For the with uncapped vials, tests tubes and well plates, only! |
test tube / plate sizes | Minimum 48 mm to 100 mm maximum |
Maximum tube
Volume |
ca. 45 ml |
Maximum flow rate | 100 ml / min (depending on viscosity and generated back pressure, max.
6 bar at the diverter valve) |
Delay volumes [μl] | Fraction collector inlet to diverter valve: ~500 (typical, depends on length of
the tubing) Diverter valve: ~15 Diverter valve to needle: ~110 Needle: ~5 |
Delay calibration Sensor | Single wavelength absorbance detector working at 654 nm, consisting of a LED and a photo diode |
Diverter valve | 3/2 Diverter valve with low internal volume (15 μl), switching time < 100 ms, maximum operating pressure 6 bar |
Cooling | Optional (with additional G1330B), performance depending on ambient conditions and the volume of collected fractions |
maximum capacity | 3 fraction collectors in parallel plus one recovery fraction collector connected via 12-Position, 13-Port Selector valve (PN G1160A) |
GLP features | Early maintenance feedback (EMF), electronic records of maintenance and
Errors |
Interfaces | Controller-area network (CAN).
optional; LAN or external contacts interfaceRS232C,APG-remote (for remote start / stop signals to / from other modules) Interface to G1330A Thermostat CAN-DC-out for operation of Agilent approved external devices like valves |
Safety features | Leak detection and safe leak handling, error detection and display, exhaust fan for fume extraction of hazardous vapors |