This refurbished Shimadzu TOC 5000A Total Organic Carbon Analyzer includes the ASI-5000A autosampler. This system will come as-is.
We have special expertise on analytical equipment. We encourage you to contact us to speak with one of our expert and professional team members.
Thanks for looking and we look forward to hearing from you!
Analyte | TC, IC, TOC (TC-IC), NPOC (non-purgeable organic carbon), POC (purgeable organic carbon: option)Method Combustion/non-dispersive infrared gas analysis method) |
Combustion temperature | 680° C |
Measuring range | 4ppb to 4000ppm (to 5000ppm for IC) (POC: Max 400ppm) |
Average analysis time | 2 to 3 minutes for both TC and IC (4.5 minutes for TC and 3.5 min. for IC at the longest) |
Repeatability | Standard deviation is less than 1% of full scale for the range less than 2000ppm to 4000ppm (from 2500ppm to 5000ppm for IC) |
Sample introduction | Automatic injection via microliter syringe |
Sample injection volume | 500 to 2000µL with a 2500 µL syringe, 4 to 250 µL with a 250 µL syringe |
Pretreatment for IC | Automatic sparging function |
Carrier gas | Cylinder of ultra-high purity air or oxygen; about 6kgf/cm2 (7kgf/cm2 max.) in supply pressure; 150 mL/min. in flow rate (300mL/min. including sparging) |
Data processing | |
Detector signal | Linearization, baseline correction, peak detection, and area calculation |
Data | Calculation of concentration using one-point to four-point calibration curve; automatic selection of best calibration curve; store up to 18 calibration curves; automatic exclusion of anomalous value(s) and automatic re-analysis/re-calculation; calculation of standard deviation and coefficient of variation, automatic re-analysis with different measurement range and/or different sample volume when response goes off scale. |
Instrument control | Aspiration, measurement, and injection sample; TC furnace temperature; ON/OFF of carrier gas and sparge gas. |
Other features | Automatic selection of the optimum set of operation conditions; maintenance/self-diagnostics, warning of abnormality; timer for restarting from the running mode. |
Display | White liquid crystal display with back-light, 640X400 dots, 88 characters x 22 lines. |
Printer | Thermal, 240-dot graphic printer, 40 characters/line, 110 mm in chart width. External dot matrix: option. |
Ambient temperature requirements | 5° to 35° C |
Power requirements | 100, 110, 115, 120, 127, 220, 230, or 240V as ordered, ±10%, 50/60Hz, about 300 VA power consumption. (800-1200VA.) |