This Agilent 1100 System is equipped with the following:
- G1322A Degasser and Solvent Tray
- G2226A NanoBin Pump
- G1389 Well Place Autosampler
- G1316A Column compartment
- G1315B DAD with nano flow cell
- Suitable software, PC, LAN Connection
- all necessary cables required for full operation
Agilent 1100 NanoBin Pump
Type | Specification |
Hydraulic system | Two dual piston in series, with proprietary servo-controlled variable stroke drive, floating piston, active inlet valve, solvent selection valve and electronic flow control for flow rates from 0.1 to 1 µl/min |
Settable column flow Range | 0.01 – 4 µl/min 1 – 2500 µl/min (with the electronic flow control bypassed) |
Recommended column flow range | 0.1 – 1 µl/min 200 – 2500 µl/min (with the electronic flow sensor bypassed) |
Optimum composition Range | 1 to 99% or 5 µl/min per channel (primary flow), whatever is greater |
Composition precision | < 0.2 % SD, at 500 nl/min (default settings), Minimum primary flow/pump channel is 5 µl/min |
Delay volume | Typically 300 nl from the electronic flow control to the pump outlet for flow rates up to 4 µl/min. For flow rates up to 4 µl/min and electronic flow control active: primary flow path 180 – 480 µl; system pressure dependent (default settings; calculated volume)Typically 180 to 480 µl (system pressure dependent) for flow rates up to 2.5 ml/min. (default settings; calculated volume) |
Pressure range | 20 to 400 bar (5880 psi) system pressure |
Compressibility compensation | User-selectable, based on mobile phase compressibility |
Recommended pH Range | 1.0 – 8.5, solvents with pH < 2.3 should not contain acids which attack stainless steel. Upper pH range is limited by fused silica capillaries |
Control and data Evaluation | Agilent ChemStation for LC |
Analog output | For pressure monitoring, 2 mV/bar, one output |
Communications | Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional |
Safety and maintenance | Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. |
GLP features | Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of seal wear and volume of pumped mobile phase with user-settable limits and feedback messages. Electronic records of maintenance and errors. |
Housing | All materials recyclable |
Agilent 1100 Series G1389 U Well PlaceAutosampler
Type | Specification |
Sample capacity | 100 x 2 ml vials in 1 tray. Microvials (100 or 300 µl) with sleeves (reduced cooling performance with microvials) |
Settable injection volume | 0.01 to 8 µl with small loop capillary 0.01 to 40 µl with extended loop capillary |
Precision | Typically < 0.5 % RSD from 5 to 40 µl Typically < 1 % RSD from 1 to 5 µl Typically < 3 % RSD from 0.2 to 1 µl |
Minimum sample volume | 1 µl from 5 µl sample in 100 µl microvial, or 1 µl from 10 µl sample in 300 µl microvials |
Carryover | Typically < 0.1 % without automated needle wash Typically < 0.05 % with external needle cleaning and 1 µl injection Volume |
Sample viscosity range | 0.2 – 5 cp |
Recommended pH-range | 1.0 – 8.5 solvent with pH < 2.3 should not contain acids which attack stainless steel. Upper pH range is limited by fused silica capillaries |
Material in contact with Solvent |
Stainless steel, sapphire, PTFE, PEEK, fused silica, Vespel |
GLP features | Early maintenance feedback (EMF),electronic records of maintenance and errors |
Communications | Controller-area network (CAN). GPIB (IEEE-448), RS232C, APG-remote standard, optional four external contact closures and BCD vial number output |
Safety features | Leak detection and safe leak handling, low voltages in maintenance areas, error detection and display |
Housing | All material recyclable |
Agilent 1100 Series G1315B DAD with nano flow cell
Type | Specification |
Detection type | 1024-element photodiode array |
Light source | Deuterium and tungsten lamps |
Wavelength range | 190 – 950 nm |
Short term noise (ASTM) Single and Multi-Wavelength |
± 1 × 10-5AU at 254 and 750 nm |
Drift | 2 × 10-3AU/hr at 254 nm |
Linear absorbance range | > 2 AU (upper limit) |
Wavelength accuracy | ± 1 nm |
Wavelength bunching | 1 – 400 nm |
Slit width | 1, 2, 4 , 8, 16 nm |
Diode width | < 1 nm |
Flow cells | Standard: 13 µl volume, 10 mm cell path length and 120 bar (1760 psi) pressure maximum Semi-Micro: 5 µl volume, 6 mm cell path length and 120 bar (1760 psi) pressure maximum Micro: 2 µl volume, 3 mm cell path length and 120 bar (1760 psi) pressure maximum High pressure: 1.7 µl volume, 6 mm cell path length and 400 bar (5880 psi) pressure maximum 80 nano: 0.08 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum 500 nano: 0.5 µl volume, 10 mm cell path length and 50 bar (725 psi) pressure maximum |
Control and data evaluation | Agilent ChemStation for LC |
Analog outputs | Recorder/integrator: 100 mV or 1 V, output range 0.001 – 2 AU, two outputs |
Communications | Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN optional |
Safety and maintenance | Extensive diagnostics, error detection and display (through control module and ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. |
GLP features | Early maintenance feedback (EMF) for continuous tracking of instrument usage in terms of lamp burn time with user-settable limits and feedback messages. Electronic records of maintenance and errors. Verification of wavelength accuracy with built-in holmium oxide filter. |
Housing | All materials recyclable |
Agilent 1100 Series Column compartment G2226A
>Type | >Specification |
Temperature range | 10 degrees below ambient to 80 °C up to 80 °C: flow rates up to 5 ml/min |
Temperature stability | ± 0.15 °C |
Temperature accuracy | ± 0.8 °C ± 0.5 °C (with calibration) |
Column capacity | Three 30 cm |
Warm-up/cool-down time | 5 minutes from ambient to 40 °C 10 minutes from 40 – 20 °C |
Dead volume |
3 µl left heat exchanger 6 µl right heat exchanger |
Communications | Controller-area network (CAN), GPIB, RS-232C, APG Remote: ready, start, stop and shut-down signals, LAN via other 1200 series module |
Safety and maintenance | Extensive diagnostics, error detection and display (through control module and Agilent ChemStation), leak detection, safe leak handling, leak output signal for shutdown of pumping system. Low voltages in major maintenance areas. |
GLP features | Column-identification module for GLP documentation of column type |
Housing | All materials recyclable |
The equipment has been tested and refurbished.
Please ask us about different warranty options for this system.
Thanks for looking and we look forward to hearing from you!