This system includes:
- Binary Pump H (VH-P10-A) or Quaternary Pump F (VF-P20-A)
- Diode Array Detector HL (VH-D10-A)
- Split Sampler HT (VH-A10-A) or FT (VF-A10-A)
- Column Compartment H (VH-C10-A)
- Charger Module (VH-A90-A)
Binary Pump H
- Rely on excellent flow accuracy and precision by ultra-precise piston drives
- Profit from built-in solvent degassing for enhanced flow stability and best detector sensitivity
- Benefit from outstanding durability for the highest system up-time with low total cost of ownership
- Forget about tedious fluidic setup thanks to innovative Thermo Scientific™ Viper™ fingertight fittings technology
Diode Array Detector HL
- Industry leading linearity with up to 2.7 AU
- Reduced interfering refractive index and thermal effects means less baseline drift and more reliable peak integration.
- Data acquisition at rates up to 250 Hz using up to 10 absorption channels and one spectral field delivers the best support of ultrafast separations.
- Easy-to-use detector with intuitive user interaction, convenient flow cell and lamp usage tracking, and the integrated wavelength validation through holmium oxide filter.
Split Sampler HT
- SmartInject technology for unrivaled retention time precision and extended column lifetime up to max. 1500bar (22,000psi)
- Out-of-the-box vial capacity of 216 samples
- Increase sample capacity to 23 well plates (up to 8832 samples) by adding the optional Thermo Scientific™ Vanquish™ Charger module
- By default, all thermostatted Vanquish Samplers utilize air stream cooling to maintain sample integrity
- Automated sample configuration using barcode reading
- Transfer of methods is incredibly easy
- Unlimited application flexibility with customizable gradient delay volume
Charger Module
- Monitor and manage an inventory of up to 9 sample racks, deep well plates, or 20 shallow well plates (15mm height) in SBS format
- Take advantage of maximum sample integrity by innovative air-stream cooling, even in challenging environments
- Gain full inventory management via barcode reading with empty shelf level detection and rack/well plate verification
- Enjoy a familiar control environment with full integration into Thermo Scientific™ Dionex™ Chromeleon™ Chromatography Data System (CDS) software
Column Compartment
- Minimal dispersion while still providing ideal heat transfer
- Active, real-time eluent preheater with a geometrical volume of 1 µL
- Negligible extra-column volume contribution even with 1 mm ID columns
- Highly effective and accurate control of the eluent temperature
- No more thermal mismatch within any LC column under any conditions
- Installation is easy with Thermo Scientific™ Viper™ connection tubing
- Fast thermal equilibration
- Best possible removal of frictional heat for reliable analyte retention
- Highest flexibility, e.g., for method transfer from other instruments