This Varian CP-3800 GC System comes with:
*Thermionic Specific Detector (TSD)
*Flame Ionization Detector (FID)
*CTC Combi Pal
*PC with Suitable software and all essential cables required for full operation
They are all in excellent condition. They have been tested at SpectraLab Scientific.
A 90 day warranty is included.
We have special expertise on analytical equipment. We encourage you to contact us to speak with one of our expert and professional team members.
Thanks for looking and we look forward to hearing from you!
Specifications
Dimensions and Weights
-Size: 53 cm (h) x 66 cm (w) x 56 cm (d)
– Weight: 43 kg
Environmental Conditions
-Operating temperatures: 10°C to 40°C
-Operating humidity (relative): 5% to 95%
-Line voltage requirements: 101V, 120V, 230V (±10% nominal)
Column Oven
-Dimensions: 28 cm (w) x 20 cm (d) x 28 cm (h)
-Temperature range: ambient +4 °C to 450 °C
-With liquid N2: -99 °C to 450 °C
-With liquid CO2: -65 °C to 450 °C
-Temperature program ramps/holds: 7/8
-Maximum temperature ramp rate: 100 °C/min for all voltages
-Cool down rate: 400 °C to 50 °C in 4.5minutes
-Temperature set-point resolution: 1 °C
Injector Options
-Maximum injectors: three operating concurrently
-Pneumatics: manual or electronic flow control (EFC)
-Columns: capillary columns standard with optional packed column adapter
-Injectors
-CP-1177Split/Splitless
-1079 Programmable Temperature Vaporizing (PTV)
-1061 Flash Megabore/Packed
-1041On-Column Megabore/Packed
CP-1177 Split/Splitless
-Pressure range: 0-100 psi
-Total flow: 500 rrillrnin at 10 psi
-Maximum temperature: 450 °C
-Split range: 1-10,000 (column dependent)
1079 Programmable Temperature Vaporizing (PTV)
-Pressure range: 0-100 psi
-Total flow: 500 mL/min at 10 psi
-Temperature range
–99 °C to 450°C liquid N2
–65 °C to 450°C liquid CO2
-Maximum temperature ramp rate: 180 °C/min
-Temperature ramps: 4
-Split range: 1-10,000 (column dependent)
-Operational modes
-Temperature ramped splitless
-Coldon-column
-Large Volurne Injection
-Split and splitless
-ChromatoProbe solid sample introduction:
optional
1061 Flash Megabore/Packed
-Pressure range: 0-100 psi
-Total Flow:50 mL/min (Type 3 EFC)
500mL/min (Type 4 EFC)
-Maximum temperature: 450 °C
1041 On-Column Megabore/Packed
-Pressure range: 0-100 psi
-Total Flow:50 mL/min (Type 3 EFC)
500mL/min (Type 4 EFC)
-Maximum temperature: 450 °C
FID
-Maximum temperature: 450 °C
-Detectivity:2 pg C/see
-Linear dynamic range: 107
-Patented ceramic -Flame tip: standard
-Flame-out detection/auto re-ignition: standard
TSD
-Maximum temperature: 450 °C
-Detectivity:
N: 100 fg N/sec (Azobenzene)
P: 100 fg P/sec (Malathion)
-Maximum temperature: 450 °C
-Linear dynamic range:
N: 105
P: 104
-Self-aligning bead: standard
Combi PAL AutoSampler
-Sample trays: two standard and expandable to four
-Tray types: 98 x 2mL vials; 200 x 1 mL vials;
32 x 10 m 1120 mL vials; and 96-well plates
-Dual and duplicate mode: standard
-Internal standard: standard
-Modes of Operation: liquid, standard; heated headspace, optional;and SPME, optional
-Sample heating and cooling: standard
-Optional modules:additional sample trays, micro-well plate holders, wach station, SPME fiberbake-out station, dilutor, barcode readers, and flowcell